Device Name

Brand  Type

Main function

Operator

Cell Sorters

(FACSAriaIIu)

BECTON DICKINSON  FACSAriaIIu 1 set
(
Laser wavelength 375 &488 & 635nm)

BECTON DICKINSON  FACSAriaIIu

BECTON DICKINSON  FACSAriaIIu 1 set
(Laser wavelength 405 &488 & 635nm)

BECTON DICKINSON  FACSAriaIIu

 ANALYSIS
including cell surface and cytoplasma analysis

    (1)Cell Marker Analysis 

    (2)Cell Cycle Analysis 

    (3)Apoptosis and Necrosis

    (4)Free Radical (ROS)

    (5)Membrane Potential

        

SORTING

    (1)general Sorting

    (2)Sterile Sorting

    (3)ACDU (clony:cell/well)

Ms. Ya-Fen Lu

extension number:
5428

Cell Analyzers

(FACSCalibur)

BECTON DICKINSON  FACSCalibur 1 set
(
Laser wavelength 488 & 635nm)

BECTON DICKINSON  FACSCalibur

ANALYSIS
including cell surface and cytoplasma analysis

    (1)Cell Marker Analysis 

    (2)Cell Cycle Analysis 

    (3)Apoptosis and Necrosis

    (4)Free Radical (ROS)

    (5)Membrane Potential

Ms. Ya-Fen Lu

extension number:
5428

Multicolor Cell Analyzers

(Attune NxT)

ThermoFisher  Attune NxT 1 set
(Laser wavelength 405 & 488 & 561 & 635nm)

ThermoFisher  Attune NxT

ANALYSIS
including cell surface and cytoplasma analysis

    (1)Cell Marker Analysis 

    (2)Cell Cycle Analysis 

    (3)Apoptosis and Necrosis

    (4)Free Radical (ROS)

    (5)Membrane Potential

    (6)whole blood analysis

        (No-Lyse-No-Wash)

      

Ms. Ya-Fen Lu

extension number:
5428

Multicolor Cell Analyzers

(BD LSR II)

BECTON DICKINSON BD LSR II 1 set
(Laser wavelength 405 & 488 & 635nm)

BD LSR II

ANALYSIS
including cell surface and cytoplasma analysis

    (1)Cell Marker Analysis 

    (2)Cell Cycle Analysis 

    (3)Apoptosis and Necrosis

    (4)Free Radical (ROS)

    (5)Membrane Potential

Ms. Ya-Fen Lu

extension number:
5428

High Content Analysis

GE Healthcare INCell Analyzer 1000 1 set
(
wavelength 350/50X & 480/40X & 555/25X & 645/30X)

GE Healthcare INCell Analyzer 1000

GE Healthcare Investigator 2 sets

GE Healthcare Investigator

IN Cell Analyzer 1000

Image acquire

    1.Lamp:Xenon 100W

    2.Microscope:Nikon TE 2000

    3.Objective:

            4X/0.210X/0.45、

            20X/0.4540X/0.6

    4.Laser autofocus

    5.CCD Camera

    6.Environment control:

         Room temperature to 42℃

         CO2 and humidity control

    7.Auto stage move:

            6-96 well plate and slide

 IN Cell Investigator

Image analysis

      Workstation version 3.6

      Developer version 1.8

Ms. Tsui-Chih Hsieh

extension number:

5191

High-Throughput Screening

PerkinElmer EnSpire 2300 1set

PerkinElmer EnSpire 2300

 

Measurable category is ALPHA LuminescenceAbsorbance

(260nm, 280nm, 405nm, 450nm,
540nm, 595nm)

Ms. Tsui-Chih Hsieh

extension number:

5191

High Throughput 
Biomolecular Interactions Analysis System

FortiBio Octet RED96 1 set

FortiBio Octet RED96

The interaction between biomolecules and biomolecular kinetics and affinity was analyzed by BLI (Bio-Layer  Interferometry). The ka, kd and KD were analyzed. After the test, the sample can be recycled.
Can be used for antigen-antibody; protein molecules and drug-protein; receptor-ligand; nuclear nucleic acid and protein; nucleic acid-nucleic acid and other molecules between the interaction analysis.

Ms. Tsui-Chih Hsieh

extension number:

5191

Sterilizer

GETINGE 733HC 955liter Sterilizer2 sets

GETINGE 733HC 955 liter Sterilizer

CASTLE M/C 3533 250liter Sterilizer1 set

CASTLE M/C 3533 110liter Sterilizer1 setCASTLE M/C 3533 Sterilizer

Can set the temperature (100 ~ 135 ℃) and drying time (0 ~ 12 hours). The average disinfection of each operation takes about 60 to 90 minutes (dry time separately)

Mr. Chi-Chen Huang

extension number:
5256

X-ray film processor

Protec Optimax, Film Processor 2 set

Protec Optimax, Film Processor

The rinseable X-ray sheet has a maximum size of 35x43 cm (14x17 inch) and a minimum of 10x10 cm (4x4 inch) for about 30 to 60 seconds.

Mr. Hsiu-Yuan Liao

extension number:
5970

Dry ice blocks Dry ice blocks
Please call to determine whether the stock is sufficient, and during the work period, that is, Monday to Friday 08:30 to 17:00 to receive. And book as much as possible three days ago to facilitate the stocking

Mr. Hsiu-Yuan Liao

extension number:
5970